Architectural Glass: Forced Entry, ArmorProtect®

Capabilities

Several test procedures evaluate glazing performance in the medium and high/maximum security institutional setting. Each one specifies the specimen size and condition, the opening size that constitutes failure, the weapons used and the number of impacts and sequence of attacks using those specified weapons. The test standard section provides a summary of the various test methods. It is essential that the design professional has a full understanding of the complete test protocol.

  Oldcastle BuildingEnvelope™ Security Laminates for use in Forced-Entry Applications
  Nominal   Max  
  HPW-TP-0500  nbsp;  ASTM UL Thickness Wt. Size  
Trade name Product# FE BR WMFL F1233 752 in. lbs/ft2 in. Assembly(1)
ArmorProtect® 111000 1-body
passage
1/2 5.4 60 x 96 AGL
ArmorProtect® 112000 1 3/4 7.2 60 x 96 AGL
ArmorProtect® 113000 1 1 9.1 60 x 96 AGL
ArmorProtect® Plus 121000 1 A(2) 7/16 4.6 60 x 96 GCP
ArmorProtect® Plus 121100 1 A(2) 9/16 5.4 60 x 96 GCP
ArmorProtect® Plus 121200 1 B(2) 11/16 6.2 60 x 96 GCP
ArmorProtect® Plus 122000 2 B(2) 3 13/16 6.4 60 x 96 GCP
ArmorProtect® Plus 123200 2 B(2) 2 15/16 7.2 60 x 96 GCP
ArmorProtect® Plus 123000 3 B(2) 3 3/4 6.3 60 x 96 GCP
ArmorProtect® Plus 123100 3 B(2) 2 7/8 7.1 60 x 96 GCP
ArmorProtect® Plus 124100 1(2) 1-1/4 10.8 60 x 96 GCP
ArmorProtect® Max 132000 2-step 14 A 3/8 2.5 60 x 96 LPC
ArmorProtect® Max 133000 3-step 16 A 1/2 3.4 60 x 96 LPC
ArmorProtect® Max 134000 4-step 38 B 3/4 5.0 60 x 96 LPC
ArmorProtect® Max 135000 5 B 2 1 6.6 60 x 96 LPC
ArmorProtect® Max 135100 5 C 2 3 1-1/4 8.2 60 x 96 LPC
HP White Test Summary
HPW-TP-0500
Forced-Entry Ballistics
Level 1: Steps 1-5 Level A: 38 Special
Level 2: Steps 1-15 Level B: 9 mm
Level 3: Steps 1-26 Level C: .44 Magnum
Level 4: Steps 1-39 Level D: 7.62 mm
Level 5: Steps 1-54 Level E: .30-06 AP
WMFL Test Summary
Level 3: 30 Minute
Level 2: 60 Minute
Level 1: 60 Minute and 25 rounds .44
              Magnum(3)
ASTM F1233 Test Summary
Forced-Entry
Class 1: Steps 1
Class 2: Steps 1-7
Class 3: Steps 1-16
Class 4: Steps 1-27
Class 5: Steps 1-41


(1) GP–glass-clad polycarbonate with exposed polycarbonate; GCP–glass-clad polycarbonate; LPC–laminated
polycarbonate; AGL–all-glass laminate.
(2) These products resisted bullet penetration. They are not designed to resist spalling.
(3) This is not a no-spall ballistics test.